Falls
the
number 1
cause of
construction
deaths Get the edge on falls
Despite variations in fatality causes and frequency, falls remain the number one killer in Ontario construction.
In Ontario construction, falls have accounted for at least 30 deaths since 1995.
1995 1996 1997 1998 Fall Fatalities 6 8 8 4 Total Fatalities 13 23 15 24 In 1999, seven of the 12 construction fatalities so far have been from falls. Ministry of Labour (MOL) inspectors have stepped up enforcement of fall protection requirements. The most important initiative is the move towards province-wide mandatory fall protection training, expected to be included in revised regulations. Prevention starts with guardrails
Guardrails are the first line of defence in fall prevention. They should be installed along the open sides of any area where a worker may fall 2.4 metres (8 feet) or more or into water, operating machinery, or hazardous substances. Areas to be protected include
Guardrails should have a top rail, mid-rail, and toeboard secured to vertical posts or supports.
Available in wood, wood-slat, wire rope, and manufactured wire mesh systems, guardrails must meet the following minimum dimensions:
These components should be secured to the inside of the posts or jacks. Toeboards should be installed on all open sides of a scaffold or work platform.
Guardrails should be installed as close to the edge as possible and must be capable of resisting any load likely to be applied. This may require extra reinforcement in special situations, such as where forklifts or buggies are used.
For maximum resistance to sideways force, the 2x4 top rail of wooden guardrails should be laid flat, with the larger dimension horizontal. To further strengthen guardrails, double the top rail and reduce the spacing of posts to between 1 and 2 metres (3 feet 4 inches and 6 feet 8 inches.)
Wood guardrails must be supported by posts extending to the top rail and braced and solidly fastened to the floor. Shoring jacks used as posts should be fitted with plywood softener plates at top and bottom. Snug up and check the posts regularly for tightness.
For slabs and the end of flying slab forms, manufactured posts can be attached to the concrete with either clamps or insert anchors.
If guardrails must be removed, the opening edge should be roped off and marked with warning signs. In addition, workers should use a fall-arrest system properly anchored and tied off.
Fall protection: two basic types
In construction, eliminating the risk of falls may not be possible. It then becomes essential to select proper fall protection.
Two basic types of fall protection are
Where guardrails or other protection is not in place, you must use a fall-arrest or travel-restraint system if you are in danger of falling
Fall Arrest
Fall arrest is the most common system. It stops a fall within a few feet of the worker's original position. A full body harness is required with a fall-arrest system. A typical system consists of the following parts connected together:
- full body harness (CSA-certified)
- lanyard (with locking snap hooks or D-clips)
- rope grab
- lifeline
- lifeline anchor.
A fall-arrest system must be worn when you are on a rolling scaffold that is being moved or when you are getting on, working from, or getting off suspended access equipment such as a swingstage or bosun's chair.
Travel Restraint
Travel-restraint systems prevent falls by restraining a worker from getting too close to an unprotected edge.
A travel restraint system must be arranged to keep the worker back from the fall hazard area. The system usually consists of
The basic problem with travel-restraint systems is that the rope grab must be continually adjusted to allow free movement and travel but still keep the worker away from the edge. One technique is to use a self-retracting lifeline (see article below).
In practice, travel-restraint systems are not foolproof because the length of the lifeline is not always adjusted properly. If the self-retracting lifeline, for instance, is longer than the distance to the nearest edge, a worker moving in that direction will not be restrained before falling.
But even if the system doesn't prevent a fall, it still arrests the fall.
Self-retracting lifelines
Self-retracting lifelines (SRLs) are widely used in construction to provide fall protection, especially where workers must move about to handle or install material. SRLs let the user move the full length of the line but stop and lock at any sudden pull. This action is designed for fall arrest -- not for travel restraint.
Users of SRLs most know the manufacturers' recommendations for proper operation as well as any safeguards required for specific applications.
SRLs have traditionally been anchored above the worker's head with the line running near vertical down to the worker's safety belt or harness. There's general agreement that this is the best application of SRLs.
In construction, however, different applications have appeared. In addition to the traditional position, two other basic options are
Each manufacturer's manual provides information and guidelines for SRLs anchored above a worker's head.
Not all of the manuals, however, cover the use of SRLs in horizontal applications. In these cases the user must confirm that the particular model is approved for horizontal use. The manufacturer will then outline requirements for proper horizontal use.
Remember -- SRLs are NOT travel restraints. Travel restraints are designed to restrain the user's movement near open edges and prevent falling altogether.
The only time an SRL can act as a travel restraint is when the line is completely drawn out yet still short enough to keep the user from moving forward or laterally into a hazardous location.
Inspection essential
Fall-arrest systems can only prevent fatal falls if they are used properly. Correct use includes inspection. Your life depends on it.
Harness
Lanyard
Most lanyards have a service life of five years. Check tag for date of manufacture. Inspect lanyard for worn, broken, or cut fibres; signs of stretching; evidence of chemical or heat damage; and cracked or distorted connecting hardware.
Shock Absorber
A shock absorber should carry a tag indicating date of last inspection. If the tag is missing, return the absorber to your supervisor for advice on its suitability. If the absorber is made with tear-away stitching designed to absorb fall-arrest load, make sure stitching is intact.
Snaphook
- Check for cracks and corroded or pitted surfaces.
- Ensure that bill and eye sections are not twisted or bent.
- Check that locking mechanism works properly. Push the keeper into the open position with the
mechanism still engaged. If the keeper opens, discard the snaphook immediately.- Ensure that spring has enough tension to close keeper securely.
- Open the keeper and release. The keeper should sit into the bill without binding.
Rope Grab
- Make sure that grabs are installed rightside up. Most grabs feature a directional arrow to indicate proper orientation.
- Ensure that proper size lifeline is used. The required size is marked on the rope grab.
- Mount the grab on the lifeline. Pull the grab down sharply. The grab should lock within 30 cm (12 inches).
Lifeline
Lifelines must be at least 16mm diameter polypropylene or material of equal strength. Inspect lines from end to end before installation. Look for cuts, burns, fraying, and chemical or heat damage. Signs of decreased diameter may indicate that line has been involved in a fall arrest and should be discarded.
Lifeline Anchorage
- Ensure that lifelines are securely attached to solid anchor points.
- Whenever possible, attach only one lifeline to each anchor.
- Never anchor to bundles of material that may be moved or depleted through use. Do not anchor to exposed rebar unless embedment length is adequate.
Back to Contents