APPLICATION OF WATERPROOF COATINGS
IN
ROOMS AND CONFINED SPACES


Hazard Summary:

Two workers have died and four have been critically injured as a result of preparing or spraying waterproof coatings in rooms or confined spaces. In all cases, the spray operators were self-employed and used portable spray equipment in trailers or trucks. These incidents occurred over the past four years.

Waterproofing products contain toluene and heptane that are toxic by inhalation and extremely flammable. The process requires stringent controls to prevent and protect against hazardous levels of contaminants.


Locations/Sectors:

Construction projects and industrial establishments where a waterproofing application is required.

This hazard occurs during the spraying application or cleaning of equipment used to apply the waterproof coatings where inadequate ventilation and a source of ignition are present.


Precautions and Legal Requirements:

Legal:


Precautions:
  1. Safe work procedures must be prepared and reviewed prior to spraying or application in a room or confined space. Workers shall receive adequate training and instruction in safe work procedures and in the use of respiratory protective equipment.
  2. Operators must be fully trained in WHMIS, equipment and procedures involving confined spaces.
  3. All sources of ignition, particularly static electricity, must be eliminated or disconnected or removed. All equipment must be properly grounded and explosion proof.
  4. The room or confined space must have adequate ventilation. The operation must NOT be carried out in unventilated areas.
  5. Appropriate personal protective equipment must be worn.
  6. Confined space requirements must be followed where applicable. Requirements include:
    • Entry by operators working alone is strictly prohibited. Operations involving confined spaces require a minimum of two persons plus a provision for rescue.
    • Entry is permitted if it is certified as safe by a competent worker or if:
      • the worker wears suitable breathing apparatus,
      • the worker wears a full body harness, securely attached to a rope, with the free end tied to a fixed support outside the confined space,
      • the worker outside the confined space is equipped with an alarm,
      • a means of communication between the worker in the confined space and the worker outside is provided,
      • a person trained in artificial respiration and equipped and able to perform rescue operations is readily available,
      • all equipment is inspected by a competent worker who confirms it is in working order
  7. Spray operations are prohibited if the concentration of vapour in the air exceeds 10% of the Lower Explosive Limit (LEL), i.e., 1000 ppm if the LEL is 1% vol/vol. Entry into confined spaces is not permitted if the concentration of flammable vapours exceeds 50% of the LEL. The work locations must be evaluated by a competent person before work in a confined space is attempted.
  8. This value will almost certainly be exceeded in unventilated areas, or where ventilation is poor or uncertain. The operation must not be attempted unless adequate mechanical exhaust ventilation is provided.
  9. Since high vapour concentrations are likely from the spray operation, the operator must wear a self-contained breathing apparatus, or a supplied-air respirator.
  10. Continuous monitoring of the level of flammable vapours is encouraged.

Remember that while complying with the occupational health and safety laws, you are also required to comply with applicable environmental laws.


© Queen’s Printer for Ontario, 2000. Permission is granted to photocopy Ministry of Labour Alerts. Please distribute them widely and post them where people will see them.

Produced by the Construction Health and safety Program, Ministry of Labour. Alert C19/0200 ISSN 1195-5228. Cette publication est également disponible en français.